abgenix.comTiter · how a medicine gets made

Stage SC · Scale
Entry SC-02

ScaleSC-02

Single-Use Changed the Plant

Disposable bags and tubing against stainless steel: what they removed, what they introduced, and how they altered what a facility looks like.

Governing number · bags vs. stainless 4 min read Stage SC of six
Single-Use Changed the Plant
Disposable bags and tubing against stainless steel: what it removed, what it introduced, and how it altered what a facility looks like.Illustration: generated

The cleaning problem that stainless steel built

A conventional biomanufacturing plant is built around permanence. The vessels are welded stainless steel, the piping is electropolished and fixed, and between every product run the entire circuit must be cleaned-in-place and steamed-in-place — CIP and SIP — to demonstrate that nothing from the last batch carries into the next. That demonstration takes time, consumes water and chemicals, and requires validation. The facility also requires substantial HVAC infrastructure to hold classified environmental grades in every room the product could touch. Commissioning a traditional large-scale facility takes years and costs hundreds of millions before a single batch is made.

Single-use technology — meaning bioprocess bags, tubing assemblies, connectors, filters and even bioreactors built on flexible plastic rather than fixed steel — attacked that problem at its root. If the surface in contact with the product is thrown away after every run, cleaning validation largely disappears. There is no prior product residue because there is no surface that was there for the prior run. CIP skids and SIP steam systems either shrink dramatically or vanish from the design entirely.

What that removes from the facility is remarkable. Fewer fixed utilities means a lighter building shell, faster construction, and a process suite that can be reconfigured by swapping assemblies rather than by scheduling a turnaround of welding and re-qualification. The floor space required to house CIP skids, clean steam generators and large fixed hold tanks compresses. For contract development and manufacturing organisations running multiple products through the same suite, this is the argument that tends to close the deal.

A stainless steel bioreactor with sanitary clamps and instrumentation, cleanroom light
The vessel is the cheap part of the room; what surrounds it sets the schedule.Photo: generated

What single-use introduced in exchange

The trade is real. Stainless steel amortises over decades; a single-use bag is a consumable cost on every batch. For a facility running at very high volume with a single mature product, the cumulative consumable spend can exceed what CIP would have cost, which is why the largest commercial manufacturing suites — 10,000-litre and above — have generally remained stainless steel even as development and clinical manufacturing moved to plastic.

Leachables and extractables are the material science problem that single-use introduced. A bag is a laminate — typically several layers including polyethylene contact surfaces — and over the course of a process run, trace compounds can migrate from the film into the product. This has to be characterised exhaustively for each assembly type and each product. In at least one documented case the industry absorbed, a leachable compound from a bag interfered with a CHO cell culture in ways that took months to trace to source. Plasticisers, antioxidants, adhesives — each layer of the laminate is a potential source, and the qualification work to satisfy regulators is not trivial.

Supply chain is the other vulnerability stainless does not have. A fixed vessel cannot be recalled or shorted; a bag is manufactured somewhere specific by a small number of suppliers, and the COVID-19 pandemic illustrated what happens to single-use supply chains when global demand surges simultaneously. Facilities with predominantly single-use operations found themselves allocating bags from constrained inventories, qualifying secondary suppliers at speed, and discovering that the flexibility single-use had promised was contingent on supply that could not always be guaranteed.

Lifted out · 01

Where the money moves

  • Fixed capital vs. consumable costsingle-use reduces construction cost but adds per-batch spend; the crossover point depends on volume and vessel size
  • Large-scale stainless still dominates at 10,000-litre and above
  • Contract manufacturers (CMOs/CDMOs) were early adopters because reconfigurability favours multi-product operations

What the plant looks like now

The practical outcome is a hybrid. Most commercial facilities built in the past fifteen years have fixed stainless vessels at scale — the main bioreactors, the large buffer hold tanks — and single-use everywhere the fluid path is short, product concentration is low, or the run is brief: seed trains, media preparation at working volumes, sampling systems, and the disposable connectors and filters that sit between unit operations. Clinical manufacturing facilities often go further toward single-use because speed to first batch matters more than consumable cost, and because the plant may be running five different molecules in a year.

The result is a facility that looks different from the picture in a 1990s textbook. Less steel, more cable ties and bag hangers. More emphasis on supply qualification and extractables characterisation. Faster to build, potentially faster to turn around between campaigns — and reliant on a supply chain that the process development team now has to treat as part of the process itself. The bag is a reagent. That shift in how the plant is conceived — from fixed infrastructure to managed consumable — is the change single-use actually brought.

A conventional biomanufacturing plant is built around permanence.

Single-use bioprocess bags on stainless frames
Bags are qualified per lot for extractables; the plastic is part of the product’s environment.Photo: Mark Stebnicki / Pexels

Lifted out · 02

Material risk

  • Leachables and extractablesthe study of what migrates from plastic films into product; required regulatory characterisation for each bag type
  • Polyethylene contact layers, laminate adhesives and antioxidants as documented sources of interference
  • The supply chain concentration risk that single-use created, exposed during COVID-19 surge demand
A chromatography skid with columns and tubing in a process suite
Between cycles the bed is stripped with caustic, on a protocol that is validated rather than improvised.Photo: Thirdman / Pexels